Test Management Environment (TME) for Release 1.345 Full Patch from 1.32x or 1.33x for 882CA




Using TME


  1. Download to PC.

  2. Unzip the contents and put them on top of the existing 1.32x or 1.33x installation.

  3. To run the TME, Double-click TME.jar

  4. To manually run the TME through a command-line Java runtime, enter:

    java -jar TME.jar

    from the TME's main folder.

Notes:
  1. The TME is run through any platform that can run executable Java JAR files. For Windows machines, this will be set up for you upon installation of the Java Runtime Environment (JRE). The TME will be displayed shortly after.
  2. The TME requires a resolution of 800x600 or higher.
  3. The TME requires Java Run Time Environment (JRE) 1.5 or later.
  4. The TME requires Firmware 20.1884202 or later (20.1884202 is the vxWorks firmware file for Release 2.8.2). However, we recommend using the latest release.
  5. The TME requires CEC and TME options on the 882CA generator. View GenStats image, verify -CEC and -TME options
    are shown. If not, contact Quantum Data for information on upgrading.
  6. Test modifications only apply to new devices. You can use the same CDFs that you have been using with the previous TME version, but you need to make a new Unit:Device object to rebuild them using the TME 1.345 system.
  7. If you have the TPA-MP-4R instead of TPA-CEC-4R, then make sure to disable EDID Formats and Emulate modes. You can press Sink -> Options to check if they are enabled or not.
  8. You will lose the CDFs you were using with TME 1.32x or 1.33x after applying the full patch. If you already have TME 1.34x, then download the patch and use that instead of this full patch.


Anomalies corrected

The following is a list of anomalies corrected as part of this patch.

  • Fixed behavior of 11.1.4-12 (missing potential check)


Other Release Notes

You can obtain Release Notes for past releases as follows:

TME 1.344
TME 1.343
TME 1.342
TME 1.34
TME 1.331
TME 1.33
TME 1.323
TME 1.321
TME 1.32
TME 1.31
TME 1.30