Latest Release Version
Release 1.6.0
Latest 980 Manager GUI Version (External and Embedded)
1.0.85
Latest Firmware Version
27.2 Build Number: 3669 7/8/2010
Latest Gateware Version
124 Build 5/26/2010
- Release 1.6.0
- 1.0.74 (Manager), 24.0 Build Number: 1552 2/1/2010 (Firmware), 69 Build 1/29/2010 (Gateware)
- 1.0.62 (Manager), 23.0 Build Number: 990 12/17/2009 (Firmware), 44 Build 12/14/2009 (Gateware)
- 1.0.60 (Manager), 20.1 Build 11/04/09 (Firmware), 12 Build 10/27/09 (Gateware)
- 1.0.46 (Manager), 10.0 Build 9/17/09 (Firmware), 7 Build 9/2/09 (Gateware)
- 1.0.44 (Manager), 10.0 Build 9/11/09 (Firmware), 7 Build 9/2/09 (Gateware)
- Sample EDID Files
This update to the 980 includes a new version of the 980 External Manager (the graphical user interface for Windows), 980 Embedded Manager for Touchscreen LCD, system components needed for touchscreen LCD unit, and a new version of the firmware/gateware load for the instrument itself. All updates should be performed at the same time, as the 980 Manager GUIs rely on some new features in the instrument firmware/gateware. Click here for the installation procedure (PDF).
This release provides the following new or improved features:
- Updated the EDID Management in the External Manager GUI per HDMI 1.4a.
- Frame viewer and Live Video now explicitly indicate if xvYCC content is being transmitted.
- Improved name selecting dialog.
- Added the ability to overwrite existing data and for captures and test results.
- Blue thumbnails representing encrypted video now show 'Q' logo to distinguish that they are generated internally.
- Data Decode
- Errors are highlighted in red, and warnings are in yellow.
- Added the ability to mark arbitrary events.
- Added the ability to search for errors and marked packets.
- Added the ability to filter on errors and marked packets.
- Improved data filtering times.
- Navigator tab
- Supports multiple selection for deletion.
- Now shows two columns, date/time capture was created and capture name.
- Added the ability to sort by column.
This load corrects the following issues:
- Fixed Deep Color issues in Live Video.
- Improved Live Video streaming stability.
- Fixed SPD InfoFrame parsing issue.
- Fixed an issue where Deep Color pixel values were not showing up correctly in Video Analysis thumbnails.
- Improved handling of special keys such as backspace in Manager GUI Console.
- Improved handling of HDCP encrypted signal capture in passthrough mode.
- Fixed an issue where video analysis thumbnails don't show up after the hot plug on capture start.
- Fixed an issue with Manager GUI Console where unexpected characters were shown.
- Fixed an issue with changing the 980's IP address using Manager GUI.
- Fixed an issue with 1080p Frame Packing 3D viewing in Live Video mode.
- Fixed invalid CEC event display in Event Plot.
- Fixed CEC filtering issue in Data Decode.
This update to the 980 includes a new version of the 980 External Manager (the graphical user interface for Windows), 980 Embedded Manager for Touchscreen LCD, and a new version of the firmware/gateware load for the instrument itself. All updates should be performed at the same time, as the 980 Manager GUIs rely on some new features in the instrument firmware/gateware. Click here for the installation procedure (PDF).
This release provides the following new or improved features:
- New Embedded Manager GUI for 980 with the touchscreen option. The Embedded Manager GUI supports Live Video functionality which allows you to view the incoming video in real-time. You can check the pixel values in real-time.
- Added EDID Editor in the External Manager GUI (not the Embedded Manager GUI). The EDID Editor lets you edit and save EDIDs that 980 can emulate. 3D and 4K x 2K information can be edited.
- Added pcap vchk enable/disable command so that you can start capturing without incoming video.
- Increased the maximum number of data island packets that 980 can handle to 18 from 8 packets.
- GUI lets the user know if a trigger occurred or not in the capture progress box.
- Added EDID decode to DDC messages.
- Improved the procedure of old log file cleanup.
This load corrects the following issues:
- Various fixes in firmware/gateware and External Manager GUI.
- Bug fixes in HDMI decode generator.
- Fixed firmware problems during timing generation in passthrough mode captures of HDCP encrypted signal.
This update to the 980 includes a new version of the 980 Manager (the graphical user interface for Windows) as well as a new version of the firmware/gateware load for the instrument itself. All updates should be performed at the same time, as the 980 Manager GUI relies on some new features in the instrument firmware. Click here for the installation procedure (PDF).
This release provides the following new or improved features:
- Removed all "PS-980" references. PS-980 is now 980.
- Added trigger on encryption enable.
- Added trigger on matched data island.
- Added the ability to emulate an EDID on the 980 Rx port via an XML file (sample EDID files are available for download below).
- Added the ability to apply a license key file (.qd.lic) to enable licensed options.
- Added Instrument information in the Navigator tab. Detailed information about the instrument is shown including licensed options.
- Added firmware/GUI version compatibility check.
- GUI no longer deletes failed captures from the PC.
- Added the ability to enter a useful name before starting a capture.
- Added the ability to rename a capture.
- Added the ability to delete a capture.
- Added a warning that timing analysis is only valid when three or more frames of data has been collected.
- Added Memory Monitor in Options menu which shows memory used/available in the status bar. It allows one to perform garbage collection (free up unused memory).
- Added capture "meta-data" log. This log gets saved as capinfo.txt in the capture folder of the PC.
- Made many buttons "repeating." You can click and hold them down without continuously clicking on them.
- Added a capture hot plug duration field in the Capture Control view.
- Video Frame Viewer
- Added the ability to put an "on-image" cursor for pixel selection by clicking on the view.
- Added buttons for fine "one pixel" cursor movement.
- Added more frame information (resolution, color depth, color space, etc.).
- Allows panning by dragging with the mouse without using the scroll bars.
- Event Plot
- Zoom/double-click no longer centers the view. The same center point is kept.
- The plot now resizes to fit the available area.
- Added paging/increment buttons.
This load corrects the following issues:
- Fixed an issue with Ethernet communications speed.
- Fixed some Console view bugs and improved failure reporting.
- Fixed a "Decode" issue where type and subtypes were reversed.
- Fixed an issue where network configuration information sometimes got corrupted.
- Fixed an issue where the "HH:MM:SS.ms.us.ns" timestamp was not calculated correctly.
This update to the 980 includes a new version of the PS-980 Manager (the graphical user interface for Windows) as well as a new version of the firmware/gateware load for the instrument itself. All updates should be performed at the same time, as the PS-980 Manager GUI relies on some new features in the instrument firmware. Click here for the installation procedure (PDF).
This release provides the following new or improved features:
- PS-980 Manager: New faster data decode access mechanism.
- PS-980 Manager: New faster event plot.
- PS-980 Manager: Deep color video support
- PS-980 Manager: YCC support
- New Audio Test
- New AVMute Test
- Encryption Disable trigger support
- TMDS pixel rate change trigger support
- External trigger in/out support
- CAM based pre-capture filtering support for data islands
- HW HDCP IP implemented
- HW FPGA initialization failure recovery
- Expanded network configuration:
- Instrument Network Configuration sets box IP address
- Edit Instrument Entry sets sets address associated with instrument name in GUI
- More accurate data time-stamping
- Extended video format and timing analyzer
- PS-980 Manager: Better and more intuitive capture navigation
This load corrects the following issues:
- Variety of bug fixes in data processing, data communication, and data presentation.
This load provides the following new feature:
- Adds CEC data type to the Event Plot.
This load corrects the following issue:
- Fixed the "Generate HotPlug on Capture Start" checkbox feature of the PS-980 Manager GUI.
Sample EDID Files
This archive contains three sample EDID files you can use for EDID emulation on the 980 Rx port.
980default_EDID.xml is the default 980 EDID.
- Maximum supported TMDS clock rate in HDMI VSDB is 165MHz.
- Supports Deep Color in HDMI VSDB.
- Supports VIC codes 1 through 62.
980nodeepcolor_EDID.xml does not support Deep Color.
- Maximum supported TMDS clock rate in HDMI VSDB is 165MHz.
- Does not support Deep Color in HDMI VSDB.
- Supports VIC codes 1 through 62.
980tmds165_EDID.xml only supports formats whose TMDS clock rate is under 165MHz in Deep Color mode.
- Maximum supported TMDS clock rate in HDMI VSDB is 165MHz.
- Supports Deep Color in HDMI VSDB.
- Supports VIC codes 1 through 62 except the following.
16 (1080p @ 59/60Hz)
31 (1080p @ 50Hz)
40 (1080i @ 100Hz)
41 (720p @ 100Hz)
46 (1080i @ 119/120Hz)
47 (720p @ 119/120Hz)
1. Download Sample EDID Files archive from here (updated on December 23, 2009).
2. Unzip the files into a new folder in your PC.
3. Turn on 980 and launch 980 Manager GUI.
4. Connect to a 980 instrument.
5. Click on File -> Set 980 EDID from PC file.
6. Browse to the location of the EDID file you want to apply to the 980 Rx port and select the XML file.
7. When asked if you want to permanently set the 980's EDID or not, clicking on Yes will replace the default 980 EDID so that the newly applied EDID will persist through power cycles. Clicking on No will let you use the newly applied EDID until you power cycle the 980 or apply another EDID.
8. When asked if you want to send hot plug or not, clicking on Yes will send a hot plug from the 980 Rx port after applying the new EDID. Clicking on No will not send a hot plug after applying the new EDID.
|
 |