The following features have been added in the Release 2.25.2.
- Added VIC details to PacketTx.
- Added IFGX:RPTU command which generates PacketTx report.
- Added GraysMHL test image which is used for MHL Sink Compliance Test.
- Modified CEC ping commands (CEC1:PING and CEC1:PING?) so that they work even if CEC ITE option is not enabled.
The following anomalies have been corrected in the Release
2.25.2.
- Fixed the issue where the reference EDID doesn't get loaded properly in VESA E-EDID Verification Test.
- Fixed the problem that occurs when switching from HDMI Deep Color mode to DVI.
- Fixed the issue where X3DM command doesn't work with Cubes3D and 3DXTalk test images.
Note: The release files can only be applied
to the 881E and 882E HDMI generator (not the 882CA/882C/881C, 882D/881D,
882EA, or 882E-DP/881E-DP generators).
The Release 2.25.2 is comprised of the following software components.
| Software Component |
Version |
Change Status |
| Boot Rom |
01.04.11 |
no change |
| vxWorks |
20.1887602 |
new with 2.25.2 |
| Gateware 1 |
404C,5,6182009 |
no change |
| Gateware 2 |
401A,19,9252008 |
no change |
| Gateware 3 |
401B,3,2282008 |
no change |
Java JRE required |
1.5.06 |
no change |
Now you can use Quantum Data's new AutoUpdate utility to upgrade
your generator firmware and gateware. The AutoUpdate utility automates the process of upgrading firmware. It guides the user through the upgrade process, checking the Quantum Data website for the latest version and installing all files in the correct location on the generator.
Read the AutoUpdate Instructions.
Download AutoUpdate Version 1.1.4 for 880 series (includes instructions)
You can upgrade your generator using the procedures in the Users
Guide. Please note that you will have to verify that your
current generator is operating with Release 2.10.0, 2.10.2,
2.10.5, 2.11.0, 2.12.0, 2.13.1, 2.15.0, 2.16.3, 2.16.4, 2.18.1, 2.19.0, 2.19.2, 2.20.0, 2.21.0, 2.22.0, 2.23.0, 2.24.1, or 2.25.0. To verify that your current
generator is operating with one of these releases, enter the
following command:
verf?
Release 2.10.0 should return the following information:
20.1884600, 01.04.11
Release 2.10.2 should return the following information:
20.1884602, 01.04.11
Release 2.10.5 should return the following information:
20.1884605, 01.04.11
Release 2.11.0 should return the following information:
20.1884800, 01.04.11
Release 2.12.0 should return the following information:
20.1885000, 01.04.11
Release 2.13.1 should return the following information:
20.1885201, 01.04.11
Release 2.15.0 should return the following information:
20.1885600, 01.04.11
Release 2.16.3 should return the following information:
20.1885803, 01.04.11
Release 2.16.4 should return the following information:
20.1885803, 01.04.11
Release 2.18.1 should return the following information:
20.1886201, 01.04.11
Release 2.19.0 should return the following information:
20.1886400, 01.04.11
Release 2.19.2 should return the following information:
20.1886402, 01.04.11
Release 2.20.0 should return the following information:
20.1886600, 01.04.11
Release 2.21.0 should return the following information:
20.1886800, 01.04.11
Release 2.22.0 should return the following information:
20.1887000, 01.04.11
Release 2.23.0 should return the following information:
20.1887200, 01.04.11
Release 2.24.1 should return the following information:
20.1887401, 01.04.11
Release 2.25.0 should return the following information:
20.1887600, 01.04.11
After verifying that the generator is operating with Release
2.10.0, 2.10.2, 2.10.5, 2.11.0, 2.12.0, 2.13.1, 2.15.0, 2.16.3, 2.16.4, 2.18.1, 2.19.0, 2.19.2, 2.20.0, 2.21.0, 2.22.0, 2.23.0, 2.24.1, or 2.25.0, upgrade your generator
using the procedures below:
- Download the 2.25.2 Zip file to your PC and unzip the
file. There will be a System and a Library directory.
- Upgrade the generator using "Upgrading without using PC Card" procedure at this link.
- After power cycling the generator, verify that the generator
is running the current 2.25.2 version of the vxWorks file
by entering the following command:
verf?
20.1887602, 01.04.11
- Verify that the vxWorks file is: 20.1887602.
- Verify that the BootRom version is: 01.04.11.
- Verify that the generator is running the current 2.25.2
version of the gateware files by entering the following
command:
verg?
404C,5,6182009:401A,19,9252008:401B,3,2282008
- The first listing is the Lattice FPGA gateware. The next
two listings are the transmitter gateware files for the
DVI and the HDMI output. The gatewares are separated by
colons. Verify that the transmitter gateware files are:
401A,19,9252008:401B,3,2282008.
The
Dolby Digital, Dolby Digital Plus, Dolby True HD, and DTS audio formats
use audio samples that must be downloaded and installed separately
to the Library/audio directory of the Compact Flash card:
- Download the file AudioSamples_2.18.1.zip
- Unzip this file to a folder in your computer
- Using FTP Browser, browse to the card0/Library
folder of the 882E generator
- Click on New under Instrument
Files, and create a new directory called
audio
- Under Host Files, browse to the folder on your PC
where you unzipped the audio sample files
- Copy all 14 files to the new audio directory
- 1khz2ch-20dB_ec3.pcm
- 1khz51ch-20dB_ec3.pcm
- 1khz71ch-1frame_ec3.pcm
- 1khz71ch-20dB_mlp.pcm
- 2khz2ch-0db_ac3.pcm
- audio.lst
- DTES-ES-48kHz-1509kbps-61ch.wav.pcm
- dts-48kHz-1509kbps-51ch.wav.pcm
- dtshdhra-48kHz-3840kbps-51ch.wav.pcm
- dtshdhra-48kHz-5376kbps-71ch.wav.pcm
- dtshdhra-96kHz-5760kbps-71ch.wav.pcm
- dtshdma-48kHz-VBR-51ch-HDMI_HBR.ba.pcm
- dtshdma-48kHz-VBR-71ch-HDMI_HBR.ba.pcm
- nxt2ch2s.mlp.pcm
- Power cycle the unit.
- Now the Dolby audio formats are ready to use by
selecting the image called
Dolby, and the DTS audio formats are ready to use by
selecting the image called
DTS
You can obtain Release Notes for past releases as
follows:
88xE Release 2.25.0
88xE Release 2.24.1
88xE Release 2.23.0
88xE Release 2.22.0
88xE Release 2.21.0
88xE Release 2.20.0
88xE Release 2.19.2
88xE Release 2.19.0
88xE Release 2.18.1
88xE Release 2.16.4
88xE Release 2.16.3
88xE Release 2.15.0
88xE Release 2.13.1
88xE Release 2.12.0
88xE Release 2.11.0
88xE Release 2.10.5
88xE Release 2.10.2
88xE Release 2.9.0
88xE Release 2.8.2
88xE Release 2.8.1
88xE Release 2.8.0
88xE Release 2.7.0
|
 |