Feature Enhancements for 882E Release 2.7.0 - vxWorks: 20.1883800

The following features are included in the Release 2.7.0.

  • Supports triple 10/12-bit per component color depth in accordance with HDMI 1.3 deep color. User Guide Section
  • Support for 20 and 24 bit audio.
  • Added 720p30, 720p29, 720p25, 720p24, and 720p23 formats.

The following anomalies have been corrected in the Release 2.7.0. Note that since this is the initial release of the 882E, none of the issues below applied to the 882E. This list below describes problems that had existed in the previous release of the 882C and 882D.

  • The Auxiliary Channel Analyzer now supports the 5 volt sense for monitoring the Hot Plug detect.
  • The anomaly associated with the SamsungB image has been corrected. The sliding white box no longer disapears when you turn off the RGB outputs.
  • The problems related to the command used to enable and disable Read EDID (TOGG) has been corrected.
  • The problem related to test sequences has been resolved. A user can no longer escape out of the test sequence menu to change other selections. Therefore a user has to exit out of the test sequence to change formats and interfaces.
  • The asterisk, indicating that an item is selected, now appears in all cases even after a power cycle.
  • The vendor specific data block in the EDID has been updated to include new data for HDMI 1.3 deep color.
  • The DCPG command now requires the DCPU command to activate it.
  • The *RST command has been updated to include all new settings. This enables a user to reset all the settings to the factory default.
  • The ringing and flickering problems on the CVBS output have been eliminated.
  • The 882 now will remove the sync signal when changing interfaces.
  • The horizontal and vertical sync pulse polarity is now set properly with HSPP and VSPP on the DVI output.
  • The anomalies that were occurring on the TVBar images at high resolution formats have been removed.
  • The anomalies that were occurring on the Master image (colors reversed) using format 480i2x29 YCbCr 4:2:2 with 8-bit depth have been corrected.
  • The ACA would occasionally hang when trying to connect to an 882 a second time. This problem has been corrected.
  • The problem of the 882 occasionally hanging when browsing the file system or scrolling through formats has been corrected.
  • Parameter values in AFDTest and PixelRep images are synchronized with queries via the command line.
  • CEC device definitions have been modified so that they no longer have potentially illegal physical addresses.

Note: The release files can only be applied to the 882E generator (not the 882C or 882D generators).



Software Table

The Release 2.7.0 is comprised of the following software components.

Software Component Version Change Status
Boot Rom 01.04.11 no change
vxWorks 20.1883800 new with 2.7.0
Gateware 1 403C,2,1052007 new with 2.7.0
Tx gateware 1 401A,8,1082007 new with 2.7.0
Tx gateware 2 401B,8,1082007 new with 2.7.0
Java JRE required 1.5.06 new with 2.7.0