Release 2.17.6 is approved by DCP for HDCP Compliance Testing.
HDCP Compliance Test notes (only applicable to 882EA with
HDCP Compliance Test option)
Applicable to all tests
- try running the tests in batch mode by using the front
panel interface
- if there is a problem, try running the tests one by one
via the command line (see the repeater AB test procedure
below as an example and refer to the user
guide)
- the test reports will be saved in /card0/library/reports
if there is a PCMCIA card inserted in the 882EA (/tffs0/library/reports/
if no PCMCIA is inserted)
Applicable to the sink tests
- you can monitor the transactions on Tx port 1 using the ACA
Applicable to the source tests
- you can monitor the transactions if you have another 882C/882CA/882E/882EA
and a TPA-MP-4R or TPA-ACA-3R
- connect the output of the source device to TPA's
port 1, the input 1 of 882EA (test equipment) to TPA's
port 2, and output 1 of a different 882C/882CA/882E/882EA
(ACA monitoring device) to TPA's port 3
- use the ACA on the 882C/882CA/882E/882EA that is not the
test equipment to monitor the transactions on Tx port 1
Applicable to the repeater AB tests
- use a separate source device and connect it to the upstream port of the repeater
- use the 882EA's Rx 1 port as the sink device and connect
it to the downstream port of the repeater via the EST
- you can monitor either downstream or upstream transactions
(not both at the same time) if you have another 882C/882CA/882E/882EA
and a TPA-MP-4R or TPA-ACA-3R
- in order to monitor the downstream transactions, connect
the downstream of the repeater device to TPA's port 1,
the input 1 of 882EA (test equipment) to TPA's port 2,
and output 1 of a different 882C/882CA/882E/882EA
(ACA monitoring device) to TPA's port 3
- in order to monitor the upstream transactions, connect
the output of the source device to TPA's port 1, the
upstream of the repeater device to TPA's port 2, and
output 1 of a different 882C/882CA/882E/882EA (ACA monitoring
device) to TPA's port 3
- use the ACA on the 882C/882CA/882E/882EA that is not the
test equipment to monitor the transactions on Tx port 1
Applicable to the repeater C tests
- connect the 882EA's Tx 1 port to the upstream port of
the repeater via the EST
- connect the 882EA's Rx 1 port to the downstream port of
the repeater via the EST
- make sure HdcpProd image is not selected on the 882EA
before running the tests
- you can monitor the downstream transactions on Rx port 1 using the ACA
- you can monitor the upstream transactions on Tx port 1 using the ACA
Sink test procedure via the command line interface
CPTX:DUTT 0 // set up for sink test
CPTX:CPTR 16 // configure 2C-1 test
CPTX:CPTU // start the test
// save the test report to the PC and rename it
// repeat above steps for test numbers 17 and 18
CPTX:CPTR 19 // configure 2C-4 test
CPTX:CPTU // start the test
// save the test report to the PC and rename it
Source test procedure via the command line interface
CPTX:DUTT 1 // set up for source test
CPTX:CPTR 1 // configure 1A-01 test
CPTX:CPTU // start the test
// save the test report to the PC and rename it
// repeat above steps for test numbers 2 to 14
CPTX:CPTR 15 // configure 1B_06 test
CPTX:CPTU // start the test
// save the test report to the PC and rename it
Repeater AB test procedure via the command line interface
CPTX:DUTT 3 // set up for repeater AB test
CPTX:CPTR 20 // configure 3A-01 test
CPTX:CPTU // start the test
// save the test report to the PC and rename it
// repeat above steps for test numbers 21 to 28
CPTX:CPTR 29 // configure 3B-05 test
CPTX:CPTU // start the test
// save the test report to the PC and rename it
Repeater C test procedure via the command line interface
CPTX:DUTT 2 // set up for repeater C test
CPTX:CPTR 30 // configure 3C1-01 test
CPTX:CPTU // start the test
// save the test report to the PC and rename it
// repeat above steps for test numbers 31 to 44
CPTX:CPTR 45 // configure 3C2-09 test
CPTX:CPTU // start the test
// save the test report to the PC and rename it
Note: The release files can only be applied
to the 882EA HDMI generator (not the 882CA/882C/881C, 882D/881D,
882E/881E, or 882E-DP generators).
The Release 2.17.6 is comprised of the following software components.
| Software Component |
Version |
Change Status |
| Boot Rom |
01.04.11 |
no change |
| vxWorks |
20.1886006 |
new with 2.17.6 |
| Gateware 1 |
405C,5,5012008 |
no change |
| Gateware 2 |
450A,1,6202007 |
new with 2.17.6 |
| Gateware 3 |
450B,1,2072008 |
no change |
Java JRE required |
1.5.06 |
no change |
The AutoUpdate utility will upgrade your 880 series generator to the most recent firmware release. Because we have
releases that are more recent than this DCP Approved version, you cannot use the AutoUpdate utility to
install this version.
See the User's Guide for full details on upgrading firmware.
You can upgrade your generator
using the procedures below:
- Download the 2.17.6 ZIP file to your PC and unzip the
file. There will be a System and a Library directory.
- Upgrade the generator using "Upgrading without using PC Card" procedure at this link.
- After power cycling the generator, verify that the generator
is running the correct 2.17.6 version of the vxWorks file
by entering the following command:
verf?
20.1886006, 01.04.11
- Verify that the vxWorks file is: 20.1886006.
- Verify that the BootRom version is: 01.04.11.
- Verify that the generator is running the current 2.17.6
version of the gateware files by entering the following
command:
verg?
405C,5,5012008:450A,1,6202007:450B,1,2072008
- The first listing is the Lattice FPGA gateware. The next
two listings are the transmitter gateware files for the
DVI and the HDMI output. The gatewares are separated by
colons. Verify that the transmitter gateware files are:
450A,1,6202007:450B,1,2072008.
The new
Dolby Digital, Dolby Digital Plus, and Dolby True HD audio formats
use audio samples that must be downloaded and installed separately
to the Library/audio directory of the Compact Flash/PCMCIA card:
- Download the file AudioSamples_2.15.0.zip
- Unzip this file to a folder in your computer
- Using FTP Browser, browse to the card0/Library
folder of the 882EA generator
- Click on New under Instrument
Files, and create a new directory called
audio
- Under Host Files, browse to the folder on your PC
where you unzipped the audio sample files
- Copy all 6 files to the new audio directory
- 1khz2ch-20dB_ec3.pcm
- 1khz51ch-20dB_ec3.pcm
- 1khz71ch-1frame_ec3.pcm
- 1khz71ch-20dB_mlp.pcm
- 2khz2ch-0db_ac3.pcm
- audio.lst
- Now the Dolby audio formats are ready to use by
selecting the image called
Dolby
You can obtain Release Notes for past releases as
follows:
882EA Release 2.16.4
882EA Release 2.16.3
882EA Release 2.15.0
882EA Release 2.13.1
882EA Release 2.12.0
882EA Release 2.11.0
882EA Release 2.10.5
882EA Release 2.10.2
|
 |