Known Issue #1: Do not enter SDMG 2; FMTU without connecting external audio to the SPDIF-IN connector first. The video output will keep refreshing itself because of a hot plug detect issue. This will be fixed in a future release.
Known Issue #2: RampDif shows green bars on the bottom ramp in YCbCr 10-bit mode. This will be fixed in a future release.
Known Issue #3: RampDif in 10-bit mode does not show correct number of bits on the bottom ramp. This will be fixed in a future release.
If you need a beta firmware that fixes the issues above, please e-mail Moon Ki Cho at mcho@quantumdata.com.
There are no new features for the 882D included in the Release 2.9.0.
The following anomalies have been corrected in the Release 2.9.0.
- Fixed the problem where our Hot Plug Detect misses some 100ms pulses.
- Fixed the problem where DCS sync does not come out on VGA interface properly.
- Fixed the problem where the HDMI 1.3a EDID Compliance Test's Test ID 8-2 shows a WARNING when the monitor name terminating byte does not equal 0x0A. A FAIL should be shown instead.
- HDMI 1.3a EDID Compliance Test's Test ID 8-3 report's wording has changed to reflect CEA-861-D properly.
- When a YCbCr bitmap is loaded, gamma correction is turned off automatically in order to show the bitmap correctly.
- Fixed the problem where 576p50 format is using ITU-709 instead of ITU-609.
- Fixed the problem where the Format Editor doesn't change PELD (pixel depth) values correctly.
Note: The release files can only be applied to the 882D
generator (not the 882CA/882C/881C or 882E/881E generators).
The Release 2.9.0 is comprised of the following software components.
| Software Component |
Version |
Change Status |
| Boot Rom |
01.04.11 |
no change |
| vxWorks |
20.1884400 |
new with 2.9.0 |
| CPLD gateware |
400C,4,6062006 |
no change |
| Tx gateware 1 |
400A,6,5042006 |
no change |
| Tx gateware 2 |
400B,10,1042007 |
no change |
Java JRE required |
1.5.06 |
no change |
You can upgrade your generator using the procedures in the Users
Guide. Please note that you will have to verify that your current
generator is operating with Release 2.3, 2.4, 2.5.x, 2.6.0, 2.7.0, 2.8.0, 2.8.1, or 2.8.2. To verify that your current generator is operating with one of these releases, enter the following command:
verf?
Release 2.3 should return the following information:
20.1883000, 01.04.11
Release 2.4 should return the following information:
20.1883200, 01.04.11
Release 2.5.4 should return the following information:
20.1883404, 01.04.11
Release 2.5.5 should return the following information:
20.1883405, 01.04.11
Release 2.6.0 should return the following information:
20.1883600, 01.04.11
Release 2.7.0 should return the following information:
20.1883800, 01.04.11
Release 2.8.0 should return the following information:
20.1884000, 01.04.11
Release 2.8.1 should return the following information:
20.1884200, 01.04.11
Release 2.8.2 should return the following information:
20.1884202, 01.04.11
After verifying that the generator is operating with either Release
2.3, 2.4, 2.5.x, 2.6.0, 2.7.0, 2.8.0, 2.8.1, or 2.8.2, upgrade your generator using the procedures below:
- Download the 2.9.0 Zip file to your PC and unzip the file. There will be a System and a Library directory.
- Upgrade the generator using the procedures at this link.
Note: You can also upgrade by transferring files using the FTP Browser.
- After power cycling the generator, verify that the generator is running the current 2.9.0 version
of the vxWorks file by entering the following command:
verf?
20.1884400, 01.04.11
- Verify that the vxWorks file is: 20.1884400.
- Verify that the BootRom version is: 01.04.11.
- Verify that the generator is running the current 2.9.0 version
of the gateware files by entering the following command:
verg?
400C,4,6062006:400A,6,5042006:400B,10,1042007
- The first listing is the CPLD gateware. The next two listings are the transmitter gateware files for the DVI and the HDMI output. The gatewares are separated by colons. Verify that the transmitter gateware files are:
400A,6,5042006:400B,10,1042007.
You can obtain Release Notes for past releases as follows:
882D Release 2.8.2
882D Release 2.8.1
882D Release 2.8.0
882D Release 2.7.0
882D Release 2.6.0
882D Release 2.5.5
882D Release 2.5.4
882D Release 2.4
882D Release 2.3
882D Release 2.2.3
|
 |