Feature Enhancements for 882D Release 2.12.0 - vxWorks: 20.1885000

There are no new features for the 882D included in the Release 2.12.0.

The following anomalies have been corrected in the Release 2.12.0.

  • Emulate Mode sets color space and sync type based on the interface and format selected. Enabling this mode will make the generator behave in the same way as release 2.4, whereas disabling this mode will make the generator behave in the same way as release 2.5.4 and later. Detailed information can be found in Chapter 2 of the user guide.
  • You can now ImageShift custom images without having to load and use them at least once.
  • MAC address information in the GenStats image/report now shows the correct address in use.
  • Default bootline user and password are now set to "anonymous" and "user" respectively.
Note: The release files can only be applied to the 882D generator (not the 882CA/882C/881C or 882EA/882E/881E generators).



Software Table

The Release 2.12.0 is comprised of the following software components.

Software Component Version Change Status
Boot Rom 01.04.11 no change
vxWorks 20.1885000 new with 2.12.0
CPLD gateware 400C,4,6062006 no change
Tx gateware 1 400A,6,5042006 no change
Tx gateware 2 400B,10,1042007 no change
Java JRE required 1.5.06 no change



Upgrade Instructions

You can upgrade your generator using the procedures in the Users Guide. Please note that you will have to verify that your current generator is operating with Release 2.3, 2.4, 2.5.x, 2.6.0, 2.7.0, 2.8.0, 2.8.1, 2.8.2, 2.9.0, 2.10.2, 2.10.5, or 2.11.0. To verify that your current generator is operating with one of these releases, enter the following command:

verf?

Release 2.3 should return the following information:

20.1883000, 01.04.11

Release 2.4 should return the following information:

20.1883200, 01.04.11

Release 2.5.4 should return the following information:

20.1883404, 01.04.11

Release 2.5.5 should return the following information:

20.1883405, 01.04.11

Release 2.6.0 should return the following information:

20.1883600, 01.04.11

Release 2.7.0 should return the following information:

20.1883800, 01.04.11

Release 2.8.0 should return the following information:

20.1884000, 01.04.11

Release 2.8.1 should return the following information:

20.1884200, 01.04.11

Release 2.8.2 should return the following information:

20.1884202, 01.04.11

Release 2.9.0 should return the following information:

20.1884400, 01.04.11

Release 2.10.2 should return the following information:

20.1884602, 01.04.11

Release 2.10.5 should return the following information:

20.1884605, 01.04.11

Release 2.11.0 should return the following information:

20.1884800, 01.04.11

After verifying that the generator is operating with either Release 2.3, 2.4, 2.5.x, 2.6.0, 2.7.0, 2.8.0, 2.8.1, 2.8.2, 2.9.0, 2.10.2, 2.10.5, or 2.11.0, upgrade your generator using the procedures below:

  1. Download the 2.12.0 Zip file to your PC and unzip the file. There will be a System and a Library directory.
  2. Upgrade the generator using the procedures at this link.
  3. After power cycling the generator, verify that the generator is running the current 2.12.0 version of the vxWorks file by entering the following command:

    verf?
    20.1885000, 01.04.11


  4. Verify that the vxWorks file is: 20.1885000.
  5. Verify that the BootRom version is: 01.04.11.
  6. Verify that the generator is running the current 2.12.0 version of the gateware files by entering the following command:

    verg?
    400C,4,6062006:400A,6,5042006:400B,10,1042007


  7. The first listing is the CPLD gateware. The next two listings are the transmitter gateware files for the DVI and the HDMI output. The gatewares are separated by colons. Verify that the transmitter gateware files are: 400A,6,5042006:400B,10,1042007.



Other Release Notes

You can obtain Release Notes for past releases as follows:

882D Release 2.11.0
882D Release 2.10.5
882D Release 2.10.2
882D Release 2.9.0
882D Release 2.8.2
882D Release 2.8.1
882D Release 2.8.0
882D Release 2.7.0
882D Release 2.6.0
882D Release 2.5.5
882D Release 2.5.4
882D Release 2.4
882D Release 2.3
882D Release 2.2.3