Feature Enhancements for 882D Release 2.10.2 - vxWorks: 20.1884602

The following features are included in the Release 2.10.2.

  • Added DMT1360H format.

The following anomalies have been corrected in the Release 2.10.2.

  • Fixed the problem where AFD test image doesn't restore state properly.
  • Fixed the problem where AV mute bit is not set when changing formats.
  • Fixed the problem where Format image's text gets chopped off on the left and top side depending on the format.
  • Fixed the problem where 10-bit YCbCr Ramp12 (grayscale mode) bottom ramp shows some green on the end.
  • Fixed the problem where 10-bit Ramp12 does not show correct number of bits on bottom ramp.
  • Changed Audio images' text so that SPDIF and I2S audio are no longer shown.
  • Fixed the problem where video resets itself if in external audio mode when no external audio is present.
  • Fixed the problem where *rst command doesn't return with a prompt in HyperTerminal.
  • Removed HDCP menu item from the main menu until the HDCP tester mode is fully functional.
  • Fixed the problem where TOGG command doesn't return with a prompt in HyperTerminal.
  • Fixed the problem where Monoscope doesn't draw properly in 1360x768.
  • Fixed some problems with HdcpProd and HDCP query.
Note: The release files can only be applied to the 882D generator (not the 882CA/882C/881C or 882EA/882E/881E generators).



Software Table

The Release 2.10.2 is comprised of the following software components.

Software Component Version Change Status
Boot Rom 01.04.11 no change
vxWorks 20.1884602 new with 2.10.2
CPLD gateware 400C,4,6062006 no change
Tx gateware 1 400A,6,5042006 no change
Tx gateware 2 400B,10,1042007 no change
Java JRE required 1.5.06 no change



Upgrade Instructions

You can upgrade your generator using the procedures in the Users Guide. Please note that you will have to verify that your current generator is operating with Release 2.3, 2.4, 2.5.x, 2.6.0, 2.7.0, 2.8.0, 2.8.1, 2.8.2, or 2.9.0. To verify that your current generator is operating with one of these releases, enter the following command:

verf?

Release 2.3 should return the following information:

20.1883000, 01.04.11

Release 2.4 should return the following information:

20.1883200, 01.04.11

Release 2.5.4 should return the following information:

20.1883404, 01.04.11

Release 2.5.5 should return the following information:

20.1883405, 01.04.11

Release 2.6.0 should return the following information:

20.1883600, 01.04.11

Release 2.7.0 should return the following information:

20.1883800, 01.04.11

Release 2.8.0 should return the following information:

20.1884000, 01.04.11

Release 2.8.1 should return the following information:

20.1884200, 01.04.11

Release 2.8.2 should return the following information:

20.1884202, 01.04.11

Release 2.9.0 should return the following information:

20.1884400, 01.04.11

After verifying that the generator is operating with either Release 2.3, 2.4, 2.5.x, 2.6.0, 2.7.0, 2.8.0, 2.8.1, 2.8.2, or 2.9.0, upgrade your generator using the procedures below:

  1. Download the 2.10.2 Zip file to your PC and unzip the file. There will be a System and a Library directory.
  2. Upgrade the generator using the procedures at this link.
  3. After power cycling the generator, verify that the generator is running the current 2.10.2 version of the vxWorks file by entering the following command:

    verf?
    20.1884602, 01.04.11


  4. Verify that the vxWorks file is: 20.1884602.
  5. Verify that the BootRom version is: 01.04.11.
  6. Verify that the generator is running the current 2.10.2 version of the gateware files by entering the following command:

    verg?
    400C,4,6062006:400A,6,5042006:400B,10,1042007


  7. The first listing is the CPLD gateware. The next two listings are the transmitter gateware files for the DVI and the HDMI output. The gatewares are separated by colons. Verify that the transmitter gateware files are: 400A,6,5042006:400B,10,1042007.