The Quantum Data 882E is packed with features for video and audio testing of HDMI® or DisplayPort sources, sinks and repeaters (HDMI). The 882E can be equipped with either an HDMI transmitter or DisplayPort 1.1 transmitter. The HDMI transmitter provides 12-bit/component deep color and NEW! HDMI 3D testing features. The DisplayPort 1.1 provides pattern testing at pixel rates up to 268MHz. An analog option with 250MHz analog output and composite analog for NTSC and PAL testing is available as well with the HDMI transmitter only configuration.
The HDMI and DisplayPort options also support an analyzer option for testing timing and video on source devices. Industry approved test tools such as HDCP compliance, CEC compliance and EDID compliance testing for HDMI are available with the HDMI analyzer. For DisplayPort the 882E analyzer option provides test tools for HDCP compliance, Link Layer compliance and EDID compliance.
Auxiliary channel monitoring is available for both digital interfaces. With the auxiliary monitoring you can view the HDCP, EDID, CEC (HDMI) and link layer (DisplayPort) transactions in real time.
View
880 Series HDMI Release Compatibility Table
|
 |
|
 |
 |
 |
|
- 3D Testing per HDMI with 3D Bitmap Conversion Tool
- Image Control Tool to fine tune deep color images (882E only).
- DTV readyPre-programmed standard DTV formats are ready for immediate use. Digital outputs support YCbCr color encoding. Analog outputs support tri-level composite sync and YPbPr.
- Built-in formatsOver 350 popular video formats are built-in including VESA, ATSC, EIA-770.x, SMPTE 170, 240, 259, 267, 274, 292, 293, 295, 296, Australian, EIA/CEA-861D, NTSC and PAL.
- Central administrationUpdate and configure all networked instruments from a single computer.
- Network controlFully control instrument from any network location with web browser or Telnet client.
- Graphics SDKCreate complex patterns based on your specifications using C++ software development kit.
- HDMIFull single-link HDMI. DVI HDCP production keys for HDMI output.
- Easy to useAccess powerful features easily using intuitive user interface.
- Multiple configurationsSave and restore different instrument configurations for different applications.
- Local pattern storageStore multiple custom images (.bmp, .jpg, and .png) images in instrument.
- Self-calibratingAnalog video outputs are automatically adjusted against an internal precision reference. This assures video levels that are precise and reliable. Signal levels are auto-adjusted individually.
- ProbeTrigger a scope or inspection camera using the probe signal. Position a pulse anywhere in the frame.
- PC CardClone one generator to another using a standard CompactFlash card.
- Auxiliary Channel Analyzer (ACA)The ACA enables you to monitor DDC, HDCP, CEC and EDID transactions for HDMI and HDCP, Link Layer and EDID transactions over the DisplayPort auxiliary channels.
- IEEE-488-GPIB (IEEE-488) interface. interface.
- RS-232-Industry standard serial interface.
|
|
|
For the 882E one of the two following digital options must be selected:
- HDMI Transmitter:
- Advanced E-EDID parsing
- 3D Pattern Testing for HDMI formats
- Deep Color at 24/30/36-bit/pixel 4:4:4 RGB / YCbCr
- 16/20/24-bit/pixel 4:2:2 YCbCr
- High-level Active Format Description (AFD) controls
- AFD test suite
- Pixel repetition test suite
- Automatic and manual InfoFrame setup
- Compressed Dolby Digital formats (Plus & TrueHD)
- Internal sine wave generator (LPCM), and external SPDIF audio input
- 32, 44.1, 48, 88.2, 176.4 and 192kHz audio sampling rates
- Generates all EIA/CEA-861D formats below 165 MHz, with all possible variations
- Complete letterbox and scope coverage
- 4:2:2 color sub-sampling at 8, 10, and 12-bits per component
- Hot-plug format list
- Includes DVI-D (M) to HDMI (M) cable and HDMI-HDMI cable.
- DisplayPort Transmitter:
- Link layer testing (compliance and monitoring)
- HDCP compliance testing of sink devices
- Pixel rates up to 268MHz
- 1, 2 & 4 lanes user selectable
- 1.62GB/s and 2.7Gb/s per lane rate user selectable
- 4:4:4 color sub-sampling
- 6, 8, and 10-bits per component
- RGB and YCbCr colorimetry
- Hot-plug format list
- Includes DisplayPort cable.
- Analog Video component and composite (882E HDMI only)
- Component analog up to 250MHz
- Component analog VGA Connector
- Composite analog on S-video and BNC Connectors
For the 882E one of the two following analyzer options can be selected:
- HDMI Analyzer available with HDMI Tx on 882E only
- Dual HDMI Tx and dual HDMI Rx ports
- Supports full single-link HDMI (with deep color) and DVI analyzer up to (150MHz) in same instrument.
- Measure source timing and source pixel errors. Also useful for testing cables. Test results can be issued as formatted reports.
- Emulate EDIDs.
- DisplayPort Analyzer available with DisplayPort Tx on 882E only
- Provides monitoring of auxiliary channel such as EDID, HDCP and link layer transactions through internal connector.
- Supports link layer compliance testing for DisplayPort source devices in addition to DisplayPort sink devices.
- Emulate VESA EDIDs.
- Single DisplayPort Tx and Single DisplayPort Rx ports
For the 882E HDMI, the following options are available:
- Options with the 882E HDMI
- CEC Integrated Troubleshooting Environment (ITE)
- Options with the 882E HDMI Analyzer
- CEC Integrated Troubleshooting Environment (ITE) - Debug environment
- CEC Test Management Environment (TME) - HDMI CEC compliance (approved by HDMI)
- HDCP compliance test - HDMI HDCP CTS 1.2
For the 882E DisplayPort, the following options are available:
- Options with the 882E DisplayPort
- VESA EDID 1.4 Verification Test
- Options with the 882E DisplayPort Analyzer
- HDCP compliance test for DisplayPort sink devices
- Link Layer compliance test for DisplayPort sink devices (VESA approved)
- Link Layer compliance test for DisplayPort sink & source devices (VESA approved)
- Auxiliary Channel Analzyer (ACA)
- VESA EDID 1.4 Verification Test
|
|
- Null Modem (p/n 30-00124)The null modem cable is provide with all 880 series generators. It is used for connecting a PC to the generator to control the generator through the command line interface.
- Ethernet cross over cable (p/n 30-00151)The Ethernet cross over cable is provide with all 880 series generators. It is used for connecting a PC to the generator for web browser access.
- Line Cord (p/n 30A00400A03)The 6 foot line cord is provided with all 880 series generators. It is a detachable power cord used to provide power to the generator.
- BNC to RCA adaptor (p/n 30-00123)The BNC to RCA adaptor is provided with 880 series generators. It is used on the TV to allow a coaxial cable connection from the TV to the generator's BNC TV output.
- DVI to HDMI adaptor (p/n 30-00145)The 6 foot DVI to HDMI cable is provided with 880 series generators. It is used to connect the generator to a DVI monitor from the generator's HDMI output connector.
- HDMI to HDMI cable (p/n 30-00146)The 6 foot HDMI to HDMI cable is provided with 880 series generators. It is used to connect the generator to an HDMI monitor from the generator's HDMI output connector.
- DisplayPort to DisplayPort cable (p/n 30-00162)The 6 foot DisplayPort to DisplayPort cable is provided with 880 series generators. It is used to connect the generator to a DisplayPort monitor or transmitter from one of the 882E DisplayPort connectors.
|
|
- ESD-1 (00-00167). Provides external ESD protection for DVI connectors.
- 128MB Compact flash memory card (82-00133 and 82-00134)
- Remote keypad (00-00123) Allow entry of numeric command to load images and formats from up to 43" (1.1 m) from the generator.
|
HDMI, the HDMI logo and High-Definition Multimedia Interface are trademarks or registered trademarks of HDMI Licensing LLC.
|
 |
|
 |
 |
|